@YvetteColomb I hope I did not come across as rude, but I believe this is one case where the downvotes are fulfilling their role without the need to actually close the question, that is neither unclear nor too broad.
That being said, that user was rude, and I don't wish to invest any more effort on their case. If you want to close/delete the question go right ahead, I don't mind.
@NobodyNada Problem is with analog/VGA, you only get a degraded quality, but still can see a picture. With digital lines, you either don't see anything at all, get block/line/etc. digital artifacts or maybe one image very some seconds only.
but looking at the spec for cat6a, it seems to say 100m as well. I recall when I purchased a 100ft run that I had researched it and the spec for it said 100ft at no attenuation, and 101- 300ft with some potential attenuation
@TylerH IIRC, it is alyways ca. 90m (300ft) for 1000baseTX. For other L1 protocols/modulation schemes it can greatly differ. You'll hardly get 90m for HDMI. Oh, and all this requires a correctly installed and connected cable. Not that it might work for longer distances or higher rates, it is just not certified. It also might degrade over time as the electirac properties change with aging insulation, etc.
@Machavity Taht's actually another dimension, you can also get CT6 as STP (foil twisted pair), even CAT5. And then ther can be another shileding around all 4 pairs together: F/FTP.
@Ron I strongly discourage let a normal electrician install network cabling! Either you do it yourse4lf, after you read some information (the LSA tool is not that expensive), or you get someone certified to do to. For a normal electrician, chances are pretty good you'll end up with 100Mbit/s max (we also had 10Mbit).
@Ron: I installed my GbE here myself. Used CAT7 as the price-difference was not that much, but it was a hell to get it into the wall plugs. Verification was simply: connect all lines with patchcables, forming one very long link and connect two PCs on each end. Then run ping for 24h with max. blocksize and max. speed. Count the losses.
@user0042 When I lived at home I had planned to run ethernet cabling under the house from where it comes into the office from outside and wire it back to my bedroom, ~100ft away
Just because such cables are sold at amazon does not mean they will work. Worse: they might work with some combination of equipment, but not other, due to tolerances.
@Ron Wait some years and see the mantle becomming brittle;-)
@TylerH It was ca. 2010 iirc the price was almost the same and the cat6(a) was not available that time. CAT5E would have worked, too, but was too much at the edge for me. I still have quite some meters on the roll somewhere stored.
@Olaf I probably need a new TV, new LAN infrastructure and someone to do all those nitty gritty things for me while I focus on important things in life - which is C++ theory.
@TylerH I am fairly new to C++. I think the committee is the one steering most of the things. Given the slow rate of adoption of new C++ standards I think it is here to stay for the foreseeable future.
There are quite a lot of questions on SO (iirc) where the top answer consists of explanations of more than one option to handle the issue. "You can do it this way, but then you have to watch out for X, the better approach would be Y because you will not have X occuring".
Does this seem like NAA? "The spec of foo changed in v1, so you can no longer bar the baz. Therefore the accepted answer is no longer valid. Does anybody know of a way to bar the baz?"