6:23 AM
you can do it with the digital analyzer/logger in the same way as you obtained the data for decoding you just use high enough sample which will be the time precision of measurement ...
in the sampled data you will see when the STM actually fires ISR and reads DB (if you set some GPIO and add it to sampled data) ... then you just look at /IOWR pulse in sampled data and see if it still fits the MCP2000 CPU IOWR cycle diagram or not if it is fast enough or not so you can decide if GPIO is OK and just need some tweaking or You have to go for bus or DMA or what ever
9 hours later…
3:44 PM
1 hour later…
5:03 PM
0.3564636875, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1 0.3564643125, 0, 0, 0, 1, 1, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 0.3564643750, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 0.3564664375, 0, 0, 1, 0, 0, 1, 0, 1, 0, 1, 1, 0, 0, 1, 1, 0 0.3564665000, 0, 0, 1, 0, 1, 1, 1, 1, 0, 1, 1, 1, 1, 1, 1, 1 0.3564665625, 1, 0, 1, 1, 1, 1, 1, 1, 0, 1, 1, 1, 1, 1, 1, 1
Time[s], IORD, IOWR, A1, CS1, CS2, RST, D0, D1, D2, D3, D4, D5, D6, D7, VO, OFF 0.0000000000, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 0.3564636250, 0, 0, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1 0.3564636875, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1 0.3564643125, 0, 0, 0, 1, 1, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 0.3564643750, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 0.3564664375, 0, 0, 1, 0, 0, 1, 0, 1, 0, 1, 1, 0, 0, 1, 1, 0 0.3564665000, 0, 0, 1, 0, 1, 1, 1, 1, 0, 1, 1, 1, 1, 1, 1, 1
it processes PortD
uint32_t data_word = GPIO-IDR
uint8_t A1 = (data_word >> 8) & 0x01;
uint8_t CS1 = (data_word >> 9) & 0x01;
uint8_t CS2 = (data_word >> 10) & 0x01;
uint8_t data_bits = data_word & 0xFF;
if ((!CS1) && (!A1)) {
LCD1_write_cmd(data_bits);
}
if ((!CS1) && (A1)) {
LCD1_write_dat(data_bits);
}
if ((!CS2) && (!A1)) {
LCD2_write_cmd(data_bits);
}
if ((!CS2) && (A1)) {
LCD2_write_dat(data_bits);
}
uint32_t data_word = GPIO-IDR
uint8_t A1 = (data_word >> 8) & 0x01;
uint8_t CS1 = (data_word >> 9) & 0x01;
uint8_t CS2 = (data_word >> 10) & 0x01;
uint8_t data_bits = data_word & 0xFF;
if ((!CS1) && (!A1)) {
LCD1_write_cmd(data_bits);
}
if ((!CS1) && (A1)) {
LCD1_write_dat(data_bits);
}
if ((!CS2) && (!A1)) {
LCD2_write_cmd(data_bits);
}
if ((!CS2) && (A1)) {
LCD2_write_dat(data_bits);
}
3 hours later…
7:48 PM
1. to measure the ISR you have to add a GPIO pin to it and also to data analyzer 2. /IOWR is pulsing per each byte ... so single pulse per single byte ... the data is changing after but those are not meant for LCD its CPU fetching instructions from memory 3. sample /iowr ,d0..d7, /cs1, /cs2, a1 , ISR_pin
use higher sampling rate so the /iowr pulse is sampled at least by ~10 samples so we can measure the time more or less acurately
_________ __________________________ /IORD \_____________/ _____________________________ ISR _____________/ \______
_________ __________________________ /IORD \_____________/ ___ ISR _____________/ \________________________________