last day (15 days later) » 

18:02
1
Q: Using a mutex to limit instance of application is not respected if one instance if started from Visual Studio

Andrew TruckleIn InitInstance of my dialog application I use this code to detect other running versions: strOwner.LoadString(IDS_APP_MUTEX); m_hMutex = ::CreateMutex(nullptr, FALSE, strOwner); HWND hOtherInstance = nullptr; if (DetectRunningInstance(hOtherInstance)) { DetectFileToOpenFromFileExplorer(); ...

Could you please remove SMTO_ABORTIFHUNG and try again? And also increase the timeout to more than 200 ms.
What's strOwner in either case?
@IInspectable That is my application mutex string. I keep that private. Sorry!
@VladFeinstein I made those changes and increased to 400. No difference. It seems to be because it has been spawned from inside VS2022.
The mutex name is not a cryptographic secret. Anyone that has access to the executable can see it by inspecting the resource section. Anyone running the application can observe the name using tools like Process Explorer or WinObj. Though the question wasn't as much about the actual value as it was whether the values are the same in either case.
Was the 'installed' version of your software also built with VS2022 or with an earlier version?
Also, I don't see and calls to ReleaseMutex(m_hMutex) or CloseHandle(m_hMutex), or handling of the call to CreateMutex failing. The last may be more sensitive in VS2022? Just guessing, really - I use a vaguely similar method to ensure a single instance and have: if ((hMutex == nullptr) || (WaitForSingleObject(hMutex, 10000) == WAIT_TIMEOUT)) return FALSE; after the call to CreateMutex - just in case.
18:02
@IInspectable They are the same because it comes from the string table.
@AdrianMole Yes with 2022.
@AdrianMole The destructor makes the call to ::CloseHandle(m_hMutex); but I never call ReleaseMutex(m_hMutex).
I guess it's time to debug (if you haven't started yet :) ). Was m_hMutex created? Was last error ERROR_ALREADY_EXISTS? Did SendMessageTimeout to YOUR window return 0? Was the result == theApp.UWM_ARE_YOU_ME_MSG? Or has it failed later?
Why use a mutex for this? Mutexes are meant for allowing only one application or thread at a time entering a "critical" piece of code, excluding the others. A more proper object imo would be a global atom, or alternatively an event. Or just use the FindWindow() function, ie search for the window class of the main frame window. Your implementation has another drawback, it sends the UWM_ARE_YOU_ME_MSG message to ALL top-level windows, not just the instances of your application.
@con A mutex is perfectly fine for this. Unlike atoms. The global atom table is severely limited in size.
@and Did you verify that they are the same? I included links to tools that help you see the names.
Does the IDS_APP_MUTEX string contain the Global prefix, eg "Global\\MyAppMutexName"?
@ConstantineGeorgiou No it doesn’t.
@IInspectable why would it not be? It is my own installer of the same project I have loaded. But it is a sensible check! Will look tomorrow.
@VladFeinstein I have done some debugging. But I will look some more tomorrow.
18:02
Just wondering why nobody but me has upvoted this very well written and interesting question.
@IInspectable With Process Explorer and running my own exe from File Explorer I was able to locate my mutex in the strings section (I saved it as a TXT and found it that way). The mutex was preceded by a /. But when I tried to perform the same action on the exe spawned from VS2022 (whether with debugging or not) the Process Explorer will not work. The strings say it is not possible to list. It gave a link to some other stuff I could install. When clicked it took me too: microsoft.com/whdc/devtools/debugging/default.mspx
I personally feel this is tied in with VS2022 because outside of that environment it is not possible for me to run multiple instances.
Don't look at the string tables. Look at the actual objects. When using Process Explorer, select the process in question and make sure the "Show Lower Pane" option is enabled. There you can see a list of all kernel objects including their names (if they are named). Mutex objects are named "Mutant".
@IInspectable Using that approach I can see mu mutex listed. But only if I run the app from File Explorer. If I run it from VS2022 that lower pane is empty.
Do you only run the program from Visual Studio or do you have a debugger attached? Does doing either one change the observed behavior? Is Visual Studio running under a different user account? Does the application when launched from Visual Studio run under a different user account? Do things change if you create the mutex into the `Global` kernel object namespace?
@IInspectable Hhm! You may be on to something. I run VS elevated.
@IInspectable That is it. If I run VS not elevated and then it is not possible to run multiple instances. But I always run VS elevated because of some of the building steps for registering DLLs. I'll try Global later.
@IInspectable Changing to Global prefix makes no difference.
18:02
That's actually what I expected. Mutexes are global per session, not per user account. What's happening is most likely that CreateMutex returns NULL in this case: If the named mutex already exists this function requests the MUTEX_ALL_ACCESS access right, which is incompatible with the ACL on the mutex created by the (presumably) elevated process. You need to update the code that checks for existence. A simple change could be if (m_hMutex == nullptr || ::GetLastError() == ERROR_ALREADY_EXISTS ) though that may not be the most accurate.
18:50
@IInspectable Thanks. That does kind of work but I am not really sure how to fit that into the real application since it will also say "Already Exists" for an instance that it can actually switch too. I will pause on this issue for now and possibly come back to this dicussion to resume a working resolution.